Minor works items - 1.56
- Jump to
- Item details
- Submission procedure
Item details
Item no. | 1.56 |
---|---|
Item class/type | Class I TypeA |
Nature of works | Erection/Alteration |
Scope of works | The works involve any external mesh fence or metal railing with or without a solid fence wall as its lower part (structure) |
Location of the structure | Located on a roof of a building |
Result in any additional load to any cantilevered slab | No |
The works involve the alteration of any other structural elements | No |
The height of the structure, including any feature at the top | Not more than 5m |
If the lower part of the structure is a solid fence wall, the height of the wall alone | Not more than 1.5m |
Other requirement | Not involve Designated Exempted Works item 18 or Minor Works item 2.56 or 3.56 |
More details: See Item 1.56 Description of building works, Schedule 1 - Part 3 - Division 1, Building (Minor Works) Regulation
Submission procedure
Step 1
Owner or their agent
Appoint Prescribed Building Professional and Prescribed Registered Contractor (Class I of Type A)
Step 2
Prescribed Building Professionals
Submit MW01 - Notice of Commencement, documents, photos 7 days before commencement of work
Step 3
Prescribed Building Professionals
Submit MW02 - Certificate of Completion, documents, photos within 14 days after completion of work