Minor works items - 2.55
- Jump to
- Item details
- Submission procedure
Item details
Item no. | 2.55 |
---|---|
Item class/type | Class II TypeA |
Nature of works | Erection/Alteration |
Location of the solid fence wall | Located on a roof of a building |
Result in any additional load to any cantilevered slab | No |
The works involve the alteration of any other structural elements | No |
The aggregate length of any additional wall per m2 of the area of the roof | Not more than 0.3m |
The thickness of the roof slab supporting the wall | Not less than 150mm |
The height of the wall | Not more than 1.5m |
The thickness of the wall | Not more than 100mm |
The density of the wall | Not more than 650kg/m3 |
Other requirement | Not involve Designated Exempted Works item 20 or Minor Works item 3.55 |
More details: See Item 2.55 Description of building works, Schedule 1 - Part 3 - Division 2, Building (Minor Works) Regulation
Submission procedure
Step 1
Owner or their agent
Appoint Prescribed Registered Contractor (Class II of Type A)
Step 2
Prescribed Registered Contractors
Submit MW03 - Notice of Commencement, documents, photos 7 days before commencement of work
Step 3
Prescribed Registered Contractors
Submit MW04 - Certificate of Completion, documents, photos within 14 days after completion of work