Minor works items - 3.40
- Jump to
- Item details
- Submission procedure
Item details
Item no. | 3.40 |
---|---|
Item class/type | Class III TypeA |
Nature of works | Erection |
Location of the block wall | In a non-domestic flat |
Result in any additional load to any cantilevered slab | No |
The works involve the alteration of any other structural elements | No |
Density of wall | Not more than 650kg per m3 |
Height of wall | Not more than 3.5m |
Thickness of wall | Not more than 100mm |
The thickness of the floor screeding of the floor slab supporting the wall | Not more than 25mm (measured from the structural floor level) |
The aggregate length of any additional wall per m2 of the floor area of the flat | More than 0.2m but not more than 0.4m |
More details: See Item 3.40 Description of building works, Schedule 1 - Part 3 - Division 3, Building (Minor Works) Regulation
Submission procedure
Step 1
Owner or their agent
Appoint and Prescribed Registered Contractor (Class III of Type A)
Step 2
Prescribed Registered Contractors
Submit MW05 - Notice of Commencement, documents, photos within 14 days after completion of work