Skip to Content

Minor Works Items

Minor Works Item - 1.50

Minor works items - 1.50

Item details

Minor Works Item - 1.50
Item no. 1.50
Item class/type Class I TypeAE
Nature of works Erection/Alteration
Location of the supporting structure or metal casing for a building services installation Located on-grade, on a canopy (other than a cantilevered slab) or on a roof (other than a cantilevered slab) of a building
The works involve alteration of any other structural elements No
In the case of a supporting structure The height of the structure
  1. for an antenna or transceiver is not more than 2.5m
  2. for other building service installation is not more than 1.5m
In the case of a metal casing
  1. the weight of the casing is not more than 10% of the weight of the installation; and
  2. the inner surface of the casing and the installation are not more than 200mm apart in all directions
Other requirement Not involve Minor Works item 3.50

Submission procedure

Owner or their agent

Appoint Prescribed Building Professional and Prescribed Registered Contractor (Class I of Type A, E)

Search for Eligible Professionals/Contractors online

Prescribed Building Professionals

Submit MW01 - Notice of Commencement, documents, photos 7 days before commencement of work

MW01 formSee sample

Prescribed Building Professionals

Submit MW02 - Certificate of Completion, documents, photos within 14 days after completion of work

MW02 formSee sample

Top