Skip to Content

Minor Works Items

Supporting structures or metal casings for a building services installation (BSI) located on-grade, on a canopy or on a roof

Contractors can only undertake the relevant classes or items of minor works for which they have been registered.

Supporting structures or metal casings for a building services installation (BSI) located on-grade, on a canopy or on a roof

Erection/Alteration
Class I

1.50

Minor Works Items 1.50

Erection/Alteration

  1. The supporting structure or casing is located on-grade/on a canopy (other than a cantilevered slab) or on a roof (other than a cantilevered slab)
  2. For the supporting structure:
    • Height of the supporting structure
      • for an antenna or transceiver
        ≤ 2.5m; or
      • for other BSI
        ≤ 1.5m; and
  3. For the casing:
    • Weight
      ≤ 10% of the weight of the BSI
    • Distance between inner surface of casing and installation
      ≤ 200mm
Class III

3.50

Minor Works Items 3.50

Erection/Alteration

  1. The supporting structure or casing is located on-grade/on a roof (other than a cantilevered slab and an inaccessible roof)
  2. For the supporting structure:
    • Design weight capacity for a BSI
      • ≤ 200kg; and
      • ≤ 100kg/m2 of the ground or slab area
    • Height of the supporting structure
      • for an antenna or transceiver
        ≤ 2.5m; or
      • for other BSI
        ≤ 1.5m; and
  3. For the casing:
    • Weight
      ≤ 10% of the weight of the BSI
    • Distance between inner surface of casing and installation
      ≤ 200mm
Removal
Class I

1.5

Minor Works Items 1.5

Removal

  1. The supporting structure or casing is located on a cantilevered slab
  2. Span of the cantilevered slab
    > 1m; and
  3. Height of the supporting structure
    Any
Class II

2.2

Minor Works Items 2.2

Removal

  1. The supporting structure or casing is located on-grade/on a canopy/on a roof
  2. (If the canopy/roof is a cantilevered slab), span of the cantilevered slab
    ≤ 1m;
  3. Height of the supporting structure
    Any
Class III

3.2

Minor Works Items 3.2

Removal

  1. The supporting structure or casing is located on-grade/on a canopy (other than a cantilevered slab) or on a roof (other than a cantilevered slab)
  2. Height of the supporting structure
    • for an antenna or transceiver
      ≤ 2.5m
    • for other BSI
      ≤ 2m

Supporting structures for air-conditioning unit, water cooling tower or any associated air ducts

Strengthening of Unauthorised supporting structures
Class III

3.34

Minor Works Items 3.34

Strengthening of Unauthorised supporting structures

  1. The supporting structure is located on-grade/on a slab (other than a cantilevered slab)
  2. Design weight capacity for an A/C unit or water cooling tower
    ≤ 100kg
Top