Minor Works Item - 3.50
Item no. 3.50
Item class/type Class III TypeAE
Nature of works Erection/Alteration
Location of the supporting structure or metal casing for a building services installation Located on-grade or on a roof (other than a cantilevered slab and an inaccessible roof) of a building
The works involve alteration of any other structural elements No
In the case of a supporting structure
  1. the weight of the building service installation is not more than 200kg and not more than 100kg per m2 of the ground or slab area
  2. the height of the structure
    1. for an antenna or transceiver is not more than 2.5m
    2. for other building service installation is not more than 1.5m
In the case of a metal casing
  1. the weight of the casing is not more than 10% of the weight of the installation; and
  2. the inner surface of the casing and the installation are not more than 200mm apart in all directions

Submission procedure

Owner or their agent

Appoint and Prescribed Registered Contractor (Class III of Type A, E)

Search for Eligible Professionals/Contractors online

Prescribed Registered Contractors

Submit MW05 - Notice of Commencement, documents, photos within 14 days after completion of work

MW05 formSee sample