Skip to Content

Minor Works Items

Minor Works Item - 2.10

Minor works items - 2.10

Class II TypeA
Forms
MW03 MW04

Item details

Minor Works Item - 2.10
Item no. 2.10
Item class/type Class II TypeA
Nature of works Construction/Alteration
Scope of works The work involve any spread footing associated with the carrying out of any other minor works or designated exempted works
Excavation depth Not more than 1.5m
The overall gradient of the area bounded by lines 10m away from the location of the footing in the downhill direction Not more than 5 degrees
Slope steepness No slope steeper than 15 degrees within the area mentioned in the above
Adjoining structure No retaining wall or terrace wall higher than 1.5m, or below a line drawn down from the base of the footing that is 45 degrees to the horizontal, within the area mentioned in above
The allowable pressure imposed by the footing on the ground Not more than 100 kPa or (if the footing is located below the ground water level) 50 kPa
Stratum The footing is not founded on soft clay or mud

Submission procedure

Owner or their agent

Appoint Prescribed Registered Contractor (Class II of Type A)

Search for Eligible Professionals/Contractors online

Prescribed Registered Contractors

Submit MW03 - Notice of Commencement, documents, photos 7 days before commencement of work

MW03 formSee sample

Prescribed Registered Contractors

Submit MW04 - Certificate of Completion, documents, photos within 14 days after completion of work

MW04 formSee sample

Top