Minor Works Item - 3.48

Minor works items - 3.48

Item details

Minor Works Item - 3.48
Item no. 3.48
Item class/type Class III TypeAE
Nature of works Erection/Alteration
Location of the external metal ventilation duct or associated supporting frame
  1. Projects from an external wall of a building
  2. Located on a balcony/verandah/canopy (other than a cantilevered slab)
  3. Hung underneath the soffit of a balcony/verandah/canopy (other than a cantilevered slab)
Result in any additional load to any cantilevered slab No
If the duct or frame projects from the external wall of a building
  1. No part of the duct or frame projects more than 600mm
  2. The distance between the highest point of the duct or frame and the ground or roof is more than 3m
If the duct or frame is located on a balcony, verandah or canopy
  1. Largest cross-sectional dimension of the duct is not more than 600mm
  2. Distance between the highest point of the duct or frame and the ground or roof is more than 3m
  3. Distance between the highest point of the duct or frame and the balcony, verandah or canopy is not more than 1.5m
  4. The balcony, verandah or canopy is not a cantilevered slab
If the duct or frame is hung underneath the soffit of a balcony, verandah or canopy
  1. Largest cross-sectional dimension of the duct is not more than 600mm
  2. Distance between the highest point of the duct or frame and the ground or roof is more than 3m
  3. The balcony, verandah or canopy is not a cantilevered slab

Submission procedure

Owner or their agent

Appoint and Prescribed Registered Contractor (Class III of Type A, E)

Search for Eligible Professionals/Contractors online

Prescribed Registered Contractors

Submit MW05 - Notice of Commencement, documents, photos within 14 days after completion of work

MW05 formSee sample