External Ventilation duct works or associated supporting frames

Contractors can only undertake the relevant classes or items of minor works for which they have been registered.

External Ventilation duct works or associated supporting frames located on grade or a roof

Erection/Alteration
Class I

1.47

Minor Works Items 1.47

Erection/Alteration

  1. Any metal ventilation duct or associated supporting frame is located on-grade/on a roof
  2. Distance between any part of the duct or frame and adjoining ground or roof
    > 2.5m
Class II

2.47

Minor Works Items 2.47

Erection/Alteration

  1. Any metal ventilation duct or associated supporting frame is located on-grade/on a roof
  2. Distance between any part of the duct or frame and adjoining ground or roof
    ≤ 2.5m
Class III

3.47

Minor Works Items 3.47

Erection/Alteration

  1. Any metal ventilation duct or associated supporting frame is located on-grade/on a roof
  2. Distance between any part of the duct or frame and adjoining ground or roof
    ≤ 1.5m
Removal
Class I

1.5

Minor Works Items 1.5

Removal

  1. Any ventilation duct or associated supporting frame is located on or hung undernath the soffit of a cantilevered slab
  2. Span of the cantilever slab
    ≥ 1m
Class II

2.2

Minor Works Items 2.2

Removal

  1. Any ventilation duct or associated supporting frame is located on-grade/on a roof
  2. (If the roof is a cantilevered slab),
    Span of the cantilevered slab
    ≤ 1m
  3. Height of the duct or frame
    Any
Class III

3.2

Minor Works Items 3.2

Removal

  1. Any ventilation duct or associated supporting frame is located on-grade/on a roof (other than a cantilevered slab)
  2. Not involve a cantilevered slab
  3. Height of the duct or frame
    ≤ 2m

External Ventilation duct works and associated supporting frames projecting from an external wall/fence wall on-grade, located on or hung underneath the soffit of a balcony/verandah/canopy

Erection/Alteration
Class I

1.47

Minor Works Items 1.47

Erection/Alteration

  1. Any metal ventilation duct or associated supporting frame is projecting from an external wall/fence wall on-grade
    • Projecting from the wall
      ≤ 750mm
  2. Any metal ventilation duct or associated supporting frame is located on a balcony/verandah/canopy
    • Largest cross-sectional dimension of the duct
      ≤ 750mm
    • Not involve a cantilevered slab
  3. Any metal ventilation duct or associated supporting frame is hung underneath the soffit of a balcony/verandah/canopy
    • Largest cross-sectional dimension of the duct
      ≤ 750mm
    • Not involve a cantilevered slab
Class III

3.48

Minor Works Items 3.48

Erection/Alteration

  1. Any metal ventilation duct or associated supporting frame is projecting from an external wall
    • Projecting from the wall
      ≤ 600mm
    • Distance between any part of duct or frame and the roof or ground > 3m
  2. Any metal ventilation duct or associated supporting frame is located on a balcony/verandah/canopy
    • Largest cross-sectional dimension of the duct
      ≤ 600mm
    • Distance between any part of duct or frame and the roof or ground
      > 3m
    • Distance between any part of duct or frame and the balcony, verandah or canopy
      ≤ 1.5m
    • Not involve a cantilevered slab
  3. Any metal ventilation duct or associated supporting frame is hung underneath the soffit of a balcony/verandah/canopy
    • Largest cross-sectional dimension of the duct
      ≤ 600mm
    • Distance between any part of duct or frame and the roof or ground
      > 3m
    • Not involve a cantilevered slab
Removal
Class I

1.5

Minor Works Items 1.5

Removal

  1. Any ventilation duct or associated supporting frame is located on or hung underneath the soffit of a cantilevered slab
  2. Span of the cantilevered slab
    > 1m
Class II

2.2

Minor Works Items 2.2

Removal

  1. Any ventilation duct or associated supporting frame is located on or hung underneath the soffit of a balcony/verandah/canopy
  2. If the balcony/verandah/canopy is a cantilevered slab, span of the slab
    ≤ 1m
Class III

3.49

Minor Works Items 3.49

Removal

  1. Any ventilation duct or associated supporting frame is located on a balcony/verandah/canopy
    • Distance between any part of duct or frame and the balcony, verandah or canopy
      ≤ 2m
    • Not involve a cantilevered slab
  2. Any ventilation duct or associated supporting frame is hung underneath the soffit of a balcony/verandah/canopy
    • Not involve a cantilevered slab
Class II

2.31

Minor Works Items 2.31

Removal

  1. Any ventilation duct or associated supporting frame is projecting from an external wall/fence wall on-grade
    • Projecting from the wall
      > 750mm
Class III

3.49

Minor Works Items 3.49

Removal

  1. Any ventilation duct or associated supporting frame is projecting from an external wall/fence wall on-grade
    • Projecting from the wall
      ≤ 750mm
Top