External non-load bearing walls (reinforced concrete walls)

Contractors can only undertake the relevant classes or items of minor works for which they have been registered.

External reinforced concrete walls

Erection/Alteration
Class I

1.15

Minor Works Items 1.15

Erection/Alteration

  1. Height of the wall
    1.1m -3.5m
Class II

2.13

Minor Works Items 2.13

Erection/Alteration

  1. Height of the wall
    ≤ 1.1m
Repair/Removal
Class I

1.15

Minor Works Items 1.15

Repair/Removal

  1. The works involve external RC wall, including any concrete projection from the wall
  2. Height of the wall
    1.1m - 3.5m
Class II

2.15

Minor Works Items 2.15

Repair

  1. The works involve external RC wall, including any concrete projection from the wall.
  2. Height of the wall
    ≤ 3.5m
  3. If involve a concrete projection
    • Thickness ≤ 125mm; and
    • Projecting from wall ≤ 150mm
Class II

2.13

Minor Works Items 2.13

Removal

  1. The works involve external RC wall
  2. Height of the wall
    ≤ 1.1m
Formation/Reinstatement of opening on an external non-load bearing wall
Class III

3.45

Minor Works Items 3.45

Formation of wall opening

  1. Distance between the 2 farthest points within the area of opening
    ≤ 150mm;
  2. For 2 or more openings, the distance between each of the openings
    ≥ 150mm; and
  3. At the completion, the no. of openings within a wall area of 1m2
    ≤ 3
Class III

3.46

Minor Works Items 3.46

Reinstatement of wall opening

  1. Distance between the 2 farthest points within the area of opening
    ≤ 150mm
Top