Skip to Content

Introduction to Minor Works Control System

Who can carry out Minor Works?

Prescribed Building Professional (PBP) and/ or Prescribed Registered Contractor (PRC), i.e. the Appointed Person, qualified to carry out the minor works are summarized as follows:

The appointed person who qualified to carry out the minor works
Appointed Person Corresponding class of minor works
Class I
Class II
Class III
Prescibed Building Professional (PBP)
Authorised Person (AP) Yes --- ---
Registered Inspector (RI)(1) Yes --- ---
Registered Structural Engineer (RSE)(2) Yes --- ---
Registered Geotechnical Engineer (RGE)(3) Yes --- ---
Prescribed Registered Contractor (PRC)
RGBC or RMWC (Company) registered for Class I Yes Yes Yes
RMWC (Company) registered for Class II --- Yes Yes
RMWC (Company) registered for Class III or RMWC (Individual) --- --- Yes

Search for Eligible Professionals/Contractors online

The submission of related document or prescribed plans should be as follows:

The submission of related document or prescribed plans
Minor Works Appointed Person Plans may be required to be submitted
Class I
Authorized Person (AP) / Registered Inspector (RI)
  • General Building Plan
  • Foundation Plan
  • Structural/ Framing Plan
  • Design Calculation and Details
  • Site Supervision plan
Class I
Registered Structural Engineer (RSE)
  • Foundation Plan
  • Structural/ Framing Plan
  • Design Calculation and Details
Class I
Registered Geotechnical Engineer (RGE)
  • Excavation Plan
  • Geotechnical Assessment Report
  • Design Calculation and Details
Class II
Class III
Registered General Building Contractor (RGBC)
  • General Building Plan
  • Floor Plan
  • Structural/ Framing Plan
  • Design Calculation and Details
Class II
Class III
Minor Works Contractor (Company)
  • General Building Plan
  • Floor Plan
  • Structural/ Framing Plan
  • Design Calculation and Details
Class III
Minor Works Contractor (Individual)
  • The Plans or Description of Works

Notes:

  1. Registered Inspector (RI) can only be appointed to supervise the prescribed repair works or any associated demolition works served with statutory notices under the Mandatory Building Inspection Scheme (MBIS) and the works covered by class I minor works items in Minor Works Control System.
  2. Registered Structural Engineer (RSE) is required to be appointed in the case of foundation plans, structural details or calculation for any class I minor works other than those specified in subsection (4) of Section 37 of B(MW)R are involved.
  3. Registered Geotechnical Engineer (RGE) is required to be appointed in the case of geotechnical plans, geotechnical assessment, geotechnical details or calculations and geotechnical reports are involved.
Top