Minor works related to Fire Safety Upgrading *

Water Tanks for Fire Services

Water Tanks for Fire Services
Minor Works Item Description
Class I
Erection/alteration of water tanks
  • material of the water tank: Glass reinforced polyester
  • located on grade or on a slab (other than a cantilevered slab)
  • capacity of the tank ≤ 4.5m3
not fall within the MW item 2.3 or DEW item 3
Class II
Replacement of water tanks
  • material of the water tank: Glass reinforced polyester
  • located on a roof
  • capacity of the tank ≤ 9m3
  • water head of the tank ≤ 2m
  • distance from the edge of the roof ≤ 1.5m
  • in accordance with the original design

Supporting Structures or Associated Metal Casings for Fire Services Installation (e.g. F.S. Pump Set and Water Tank)

Supporting Structures or Associated Metal Casings for Fire Services Installation (e.g. F.S. Pump Set and Water Tank)
Minor Works Item Description
Class I
Erection/alteration of supporting structures or associated metal casings for a building services installation (BSI)
  • the supporting structure or casing is located on-grade or on a roof (other than a cantilevered slab)
  • for the supporting structure:
    • height of the supporting structure ≤ 1.5m;
  • for the casing:
    • Weight ≤ 10% of the weight of the BSI
    • Distance between inner surface of casing and installation ≤ 200mm apart in all directions
not fall within the MW item 3.50
Class III
Erection/alteration of supporting structures or associated metal casings for a BSI
  • the supporting structure or casing is located on-grade/on a roof (other than a cantilevered slab and an inaccessible roof)
  • for the supporting structure:
    • design weight capacity for a BSI
      • ≤ 200kg;
      • ≤ 100kg/m2 of the ground or slab area
    • height of the supporting structure ≤ 1.5m;
  • for the casing:
    • weight ≤ 10% of the weight of the BSI
    • distance between inner surface of casing and installation ≤ 200mm apart in all directions

Fixed Lights or Top Vents

Fixed Lights or Top Vents
Minor Works Item Description
Class I
Erection, alteration or removal of any protective barrier (within 1.1m from floor) (other than an external reinforced concrete wall or block wall) and the works do not result in any additional load to cantilevered slab
Class II
Construction, alteration, repair or replacement of windows or window walls
  • highest point from ground: > 3.5 m - 100m
    • the span of structural element of window or window wall ≤ 6m
    • the works involve main frame or sub-frame of window or window wall (length of sub-frame > 1.2m)
  • highest point from ground: > 100m
    • the span of structural element of window or window wall > 6m
    for construction or alteration
    • the area of the external wall opening for window or window wall ≤ 6m2; and
    • the length of shorter side of the opening ≤ 1.8m
    for repair or replacement
    • if not in accordance with the original design
      • area of the external wall opening for the window ≤ 6m2; and
      • length or width (whichever is shorter) of the opening ≤ 1.8m; or
    • in accordance with the original design
Class III
Construction, alteration, repair or replacement of windows or window walls
  • highest point from ground: ≤ 3.5m
    • the span of structural element of window or window wall ≤ 6m
  • highest point from ground: > 3.5m - 100m
    • the works involve the sub-frame of window or window wall (length of sub-frame ≤ 1.2m)

External Non-Load Bearing Walls Openings for Fixed Lights, Top Vents or F.S. Pipes

External Non-Load Bearing Walls Openings for Fixed Lights, Top Vents or F.S. Pipes
Minor Works Item Description
Class I
Erection/alteration/removal of external reinforced concrete walls
  • height of the wall 1.1m - 3.5m
not fall within the MW items 2.15, 3.45 or 3.46
Class II
Erection/alteration/removal of external reinforced concrete walls
  • height of the wall ≤ 1.1m
not fall within the MW items 3.45 or 3.46
Class II
Erection/alteration/removal of external block walls
  • height of the wall 1.1m - 3.5m
not fall within the MW items 3.45 or 3.46
Class III
Erection/alteration/removal of external block walls
  • height of the wall ≤ 1.1m
not fall within the MW items 3.45 or 3.46
Class III
Formation of openings on an external non-load bearing walls
  • distance between the 2 farthest points within the area of opening ≤ 150mm;
  • for 2 or more openings, the distance between each of the openings ≥ 150mm; and
  • at the completion, the no. of openings within a wall area of 1m2 ≤ 3

Non-Load Bearing Block Walls

Non-Load Bearing Block Walls
Minor Works Item Description
Class I
Erection of Non-load bearing block wall
for both domestic flat or non-domestic flat
aggregate length of additional wall per m2 of the floor area of the flat
  • > 0.1m for domestic flat or
  • > 0.2m for non-domestic flat,
not fall within the MW items 3.39 or 3.40
Class III
Erection of Non-load bearing block wall
for domestic flat
aggregate length of additional wall per m2 of the floor area of the flat
  • > 0.1m but ≤ 0.3m
Class III
Erection of Non-load bearing block wall
for non-domestic flat
aggregate length of additional wall per m2 of the floor area of the flat
  • > 0.2m but ≤ 0.4m

Openings to Staircases or Lobbies

Openings to Staircases or Lobbies
Minor Works Item Description
Class I
Formation/alteration of openings to staircases/lobbies
  • opening to the enclosure of staircase that is used as a means of escape or a means of access for firefighting and rescue or its protected lobby

Openings in Slab for Smoke Outlets

Openings in Slab for Smoke Outlets
Minor Works Item Description
Class I
Formation of openings in a slab
area of opening
  • > 1m2 but ≤ 4.5m2
Class II
Formation of openings in a slab
area of opening
  • ≤ 1m2
not fall within the DEW item 1

Fire Dampers in Ventilation System

Fire Dampers in Ventilation System
Minor Works Item Description
Class II
Erection/alteration of fire dampers in ventilation system
  • Any fire damper in a ventilation system

*For minor works to be carried out including but not limited to compliance with Fire Safety Directions/Fire Safety Improvement Directions issued under Fire Safety (Commercial Premises) Ordinance, Fire Safety (Buildings) Ordinance and Fire Safety (Industrial Buildings) Ordinance.

More details: See Fire Safety

For minor works carried out at common parts of a building, the person who arranged the works to be carried out or his appointed agent (including the PBP/PRC) should seek consent from all owners and the management company of the building and observe all duties as stipulated in the deed of mutual covenant.